ZYU8843 Series
A high-output universal AC motor platform for appliance applications requiring very high speed, strong airflow and compact power density.

Measured operating points
Representative test data from the ZYU8843 catalog configuration. Final performance should be confirmed against the actual appliance load and duty cycle.
| Parameter | No Load | Max Efficiency | Max Output | Max Torque |
|---|---|---|---|---|
| Speed (RPM) | 26,670 | 15,314 | 10,691 | 10,691 |
| Torque (N·m) | 0.04 | 0.40 | 0.88 | 0.88 |
| Output Power (W) | 101.12 | 642.35 | 985.92 | 985.92 |
| Voltage (V) | 119.63 | 119.24 | 118.39 | 118.39 |
| Current (A) | 2.91 | 7.85 | 13.93 | 13.93 |
| Input Power (W) | 345.94 | 904.59 | 1,557.10 | 1,557.10 |
| Efficiency | 29.23% | 71.01% | 63.32% | 63.32% |
| Power Factor | 0.99 | 0.97 | 0.94 | 0.94 |
Outline drawing and performance curve
Review the main mounting dimensions, performance curve and test operating points for the catalog ZYU8843 configuration. Use this information for preliminary selection; final construction and performance require project confirmation.

Motor outline drawing
View the principal dimensions, shaft, mounting-hole and rotation references from the catalog.
View outline drawing →
Performance curve and data
View speed, torque, input power, shaft output and efficiency data for the catalog test configuration.
View performance data →Catalog drawings and performance data are for preliminary evaluation and do not constitute a production specification. Final dimensions, tolerances, winding and operating point require project validation.
Request CAD / detailed datasheet →Designed for demanding appliance integration
26,670 RPM measured at the representative no-load test point.
Up to 985.92 W output in the representative catalog test.
Maximum-efficiency operating point recorded in catalog testing.
Designed for compact OEM products requiring substantial output.
A strong starting platform for fan and airflow-related appliances.
Current product-page configuration is specified as clockwise (CW).
Validate high output in the complete product
ZYU8843 is a high-speed, high-output catalog reference. The final motor should be assessed as part of the complete appliance, including the real load, supply, cooling path, mounting stiffness, acoustic target and operating cycle.
Good starting applications
- High-output appliance mechanisms with a defined load profile
- Airflow-intensive products with an engineered cooling path
- Compact systems requiring a broad performance envelope
Points requiring engineering review
- Supply current, loaded operating point and start-up behavior
- Temperature rise, cooling airflow and protection strategy
- Noise, vibration, mounting stiffness and balance
- Duty cycle, life target and market compliance
Alternative starting points
ZYU7635 Series
Compare a lower-output, higher-torque reference when the required envelope and load are more moderate.
View ZYU7635ZYU8840-D80 Series
Review the related 88-frame platform when its construction or operating point better fits the product.
View ZYU8840-D80ZYU9422 Series
Consider the adjacent larger platform when the mechanical package or performance requirement differs.
View ZYU9422Is ZYU8843 the right starting platform?
Send your target voltage, speed, torque, duty cycle, mechanical envelope, project stage and estimated annual demand for motor matching support.