ZI8260 Series
A 120V / 60Hz induction motor reference for OEM mechanisms requiring lower speed and substantial loaded torque. Final suitability depends on the driven load, starting conditions, installation and duty cycle.

Measured operating points
Representative test data from the ZI8260 catalog configuration. Final motor selection and performance should be confirmed against the actual appliance load and duty cycle.
| Parameter | No Load | Max Efficiency | Max Output | Max Torque | Min Torque |
|---|---|---|---|---|---|
| Speed (RPM) | 3,559 | 3,269 | 2,909 | 2,603 | 1,210 |
| Torque (N.m) | 0.07 | 0.95 | 1.39 | 1.46 | 0.89 |
| Output Power (W) | 27.55 | 325.10 | 423.28 | 397.52 | 112.73 |
| Voltage (V) | 120 | 120 | 120 | 120 | 120 |
| Current (A) | 1.67 | 4.00 | 6.08 | 7.24 | 8.72 |
| Input Power (W) | 182.56 | 475.03 | 724.23 | 859.60 | 1022.80 |
| Efficiency | 15.09% | 68.44% | 58.45% | 46.25% | 11.02% |
| Power Factor | 0.91 | 0.99 | 1.00 | 0.99 | 0.98 |
Outline drawing and performance curve
Review the main mounting dimensions, performance curve and test operating points for the catalog ZI8260 configuration. Use this information for preliminary selection; final construction and performance require project confirmation.

Motor outline drawing
View the principal dimensions, shaft, mounting-hole and rotation references from the catalog.
View outline drawing →
Performance curve and data
View speed, torque, input power, shaft output and efficiency data for the catalog test configuration.
View performance data →Catalog drawings and performance data are for preliminary evaluation and do not constitute a production specification. Final dimensions, tolerances, winding and operating point require project validation.
Request CAD / detailed datasheet →Review the complete driven mechanism
Confirm starting conditions, acceleration and loaded torque in the complete mechanism.
Use the measured operating points as references for matching the driven load.
Catalog construction focused on stable performance and durability.
Representative catalog test configuration uses clockwise rotation.
Confirm the cooling path and temperature rise under the intended duty cycle.
Protection configuration can be evaluated for the target application.
Match the lower-speed platform to the real mechanism
ZI8260 is a 120V catalog reference with a lower-speed, higher-torque operating range. Selection should be based on the driven mechanism, start-up load, transmission interface, cooling and operating cycle.
This platform may suit
- OEM mechanisms requiring lower speed and substantial loaded torque
- Products with a defined transmission or driven interface
- Applications where clockwise rotation matches the mechanism
Confirm before selection
- Start-up torque, current and loaded speed
- Shaft, mounting and transmission geometry
- Cooling path and repeated-cycle temperature rise
- Noise, vibration, life and compliance targets
Compare adjacent motor options
Use these catalog platforms as engineering references before sample validation.
ZU9535-C72
Compare the high-speed 120V configuration when the load profile differs.
View product detailsZB8550
Review the 220V ZB brushless platform when a different speed and output range is required.
View product detailsZU9422
Consider an alternative 110V platform with a different speed and torque balance.
View product detailsIs ZI8260 the right starting platform?
Send your target voltage, speed, torque, duty cycle, mechanical envelope, project stage and estimated annual demand for motor matching support.
Talk with Our Motor Engineering Team
Mobile: +86 135 1010 9191
Landline: +86 755 2919 9128